Category: Design
Prepared by Eng. Ahmed Fathy, Projects Manager ·
Definition
A storage heater serves demand from stored hot water while reheating it. Selection considers usage pattern, recovery and storage, together with support, protection and maintenance.
Why it matters on a project
Tank volume alone does not determine hot-water delivery during peak demand.
Measurement and pricing
Review capacity, heat input, performance data, water conditions, electrical supply and safety provisions against the product and design.
Worked example
For ideal heating energy only, 100 kg of water rises by 30 degrees Celsius using specific heat 4.18 kJ/kg.K: energy is 100 × 4.18 × 30 = 12540 kJ, or 12540 ÷ 3600 = 3.483333 kWh approximately. Losses are excluded; these figures do not set a safe operating temperature.
Common mistake
Selecting only by tank litres or obstructing a safety-valve discharge.
Frequently asked questions
Are litres enough for sizing?
No. Review peak demand, recovery, inlet temperature and distribution.
Can a relief valve be obstructed?
No. Provide protection and discharge according to the heater system and instructions.
Related terms
- MEP drawingsElectrical, plumbing, HVAC and fire drawings.
- Electrical load scheduleA table summing each board's loads to size breakers, cables and the meter.
- Equipment access clearanceSpace needed to reach equipment and remove its components safely.
Read next
Does your project need architectural design and construction drawings? Send the drawings or a short description and we reply within one working day.
Service detailsRequest a quote