Illuminance in lux

الاستضاءة باللوكس

Incident luminous flux per unit area.

Category: Design

Prepared by Eng. Ahmed Fathy, Projects Manager ·

Definition

Illuminance is measured on a defined plane such as a desk or floor. Layout, reflections, mounting height and maintenance affect it; average and minimum values differ.

Why it matters on a project

Lamp output alone does not establish light reaching the task surface.

Measurement and pricing

Use a defined measurement grid and plane, recording operating state, daylight and instrument calibration.

Worked example

For the unit definition only, 6000 lumens incident uniformly on 20 m² gives 6000 ÷ 20 = 300 lux. This is flux reaching the surface, not lamp lumens before losses.

Common mistake

Treating one reading beneath a luminaire as the room average.

Frequently asked questions

Are lux and lumens identical?

Lux is lumens per square metre of receiving surface.

Is daylight included in testing?

Record and control daylight according to the measurement purpose and method.