Definition
Drain invert level is the elevation of the lowest internal flow surface relative to the project datum. It differs from pipe centreline and external bottom levels and controls gravity drainage between points.
Why it matters on a project
Misreading it can create reverse falls or prevent connection to an existing chamber.
Measurement and pricing
Measure inlet and outlet inverts and horizontal distance, then calculate gradient. Convert external measurements using actual pipe dimensions.
Worked example
Upstream invert is 100.50 m with 12 m horizontal run and assumed design fall of 1%: fall is 12 × 1 ÷ 100 = 0.12 m and downstream invert is 100.50 − 0.12 = 100.38 m. This does not prescribe an acceptable gradient for any diameter.
Common mistake
Confusing pipe crown with invert or using nominal size instead of actual dimensions for conversion.
Frequently asked questions
Is invert level the excavation level?
No. Excavation accounts for pipe wall, bedding and the approved detail.
How is an existing chamber connection checked?
Survey actual levels and dimensions first, then review the connection with the designer.